Portfolio
Selected Kyiv projects where design, installation, and tuning delivered measurable comfort.
Video/PhotoVARUS, Parkove Misto: installation of 2 Cooper&Hunter modular chillers, 140 kW
CaseCalculation, design, installation, and commissioning of a supermarket cooling system based on 2 Cooper&Hunter modular chillers with a total capacity of 140 kW.
Open case
Video/PhotoOffice building in Vyshneve: MYCOND ventilation and a Haier multi-zone system (MRV)
CaseDesign, installation, and commissioning of indoor climate systems for a two-storey office building with a dining area, office and utility rooms, and a mini server room: each floor is equipped with a MYCOND ventilation system with heat recovery and additional air reheating (1,000 m³/h per floor), a Haier multi-zone heating/cooling system with an estimated capacity of 70 kW, and separate Haier-controlled cooling for the mini server room.
Open case
Video/PhotoOffice on Vavilovykh Street: 60 kW Haier multi-zone system and VENTS ventilation
CaseDesign, installation, and commissioning of indoor climate systems in an office space: a Haier multi-zone system with an estimated capacity of 60 kW for heating and cooling, a VENTS air-handling unit rated at 1,000 m³/h with heat recovery, additional exhaust systems, and mini server room cooling. The main ventilation is exposed.
Open case
PhotoVeterinary pharmaceuticals warehouse: Haier multi-zone system with backup and alert systems
CaseDesign, installation, and commissioning of systems for a warehouse storing veterinary medicines and raw materials: a Haier multi-zone heating and cooling system with backup and alert systems, supply ventilation with heating via the evaporator, and exhaust systems with automatic electric dampers.
Open case
PhotoSchool in Kniazhychi: 6,000 m³/h shelter ventilation built from Aerostar components
CaseDesign, installation, and commissioning of supply and exhaust ventilation for a school basement used as a temporary shelter: system capacity 6,000 m³/h to supply air for a room intended for long stays by children. The system is assembled from AEROSTAR components.
Open case
PhotoBratislava Hotel: 9,000 m³/h ROTOR ventilation and conference hall cooling
CaseDesign, installation, and commissioning of indoor climate systems for the hotel's conference halls after renovation: 9,000 m³/h supply and exhaust ventilation with a rotary heat exchanger, a chiller-fan coil cooling system, and connection to the existing chiller.
Open case
PhotoRehabilitation center: 6,000 m³/h VTS ventilation and a Haier multi-zone system
CaseDesign, installation, and commissioning of engineering systems for a rehabilitation center: a 6,000 m³/h VTS air-handling unit with a plate heat exchanger and a Haier multi-zone system for heating and cooling with an estimated capacity of 80 kW.